TM 5-6350-275-24&P
(6) Connect red and black wires slip-on terminal lugs to positive and negative terminals (26) of 12 vdc battery
(25).
(7) Download the RSE data to Stargate 5000 PWA (1). (See paragraph 3-138 for RSE download procedures)
(8) Place front access cover on enclosure and secure.
3-57. REPLACE STARGATE 5000 PWA.
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
AC Adapter disconnected
Remove all jewelry while working on equipment.
Enclosure cover removed
Wear ESD wriststrap while working on equipment.
Tools:
Screwdriver, Flat tip (Item 6, App B)
Materials/Parts:
Screwdriver, Flat tip (Item 7, App B)
Stargate 5000 PWA
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Tag and remove cable connectors from Comms jack (24), AUX-0 jack (23), and AUX-1 jack (22) by lifting
straight up on connectors.
(2) Remove slip-on terminal strips from TB-50 (21), TB-7 (20), TB-8 (19), TB-9 (18), and TB-1 (2) by lifting up
on terminal strips.
(3) Using a flat tip screwdriver remove the green ground wire (14) and screw (15) from the Stargate 5000
PWA (1).
(4) Press in and hold latching mechanism (16) down, while gently lifting up on PWA (1). Do this for each of
five fasteners until PWA can be removed from standoffs.
(5) Place the removed Stargate PWA (1) into a ESD protective bag.
b. Installation
(1) Set the Link Setting and/or Switch Setting exactly the same as removed assembly or refer to Appendix E,
page E-33.
(2) Place the Stargate PWA (1) on plastic standoffs and gently press down on PWA until each of the latching
mechanism (16) locks into place.
(3) Connect green ground (14) wire to Stargate PWA using removed screw (15).
3-138