REPLACE MOD 2 MODEM PWA. (Figure 3-40).
REPLACE 12 VDC BATTERY. (Figure 3-40).

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  208    209    210    211    212  213  214    215    216    217    218  
img
. . . . . . . .
TM 5-6350-275-24&P
3-59. REPLACE 18 VAC ADAPTER. (Figure 3-40 and FO-7).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
AC Adapter disconnected from power source
Remove all jewelry while working
Enclosure cover removed
on equipment.
Tools:
Wear ESD wriststrap while working on equipment.
Screwdriver, Flat tip (Item 6, App B)
Wire cutters (Item 24, App B)
Materials/ Parts:
Tie Wraps (App D, item 13)
18 VAC Adapter
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Using a flat tip screwdriver, loosen the two screws on TB-1 (2) pins 1 and 2 and remove the two AC
adapter input wires (FO-7).
(2) Cut the plastic tie wraps (as necessary) and remove the AC adapter wires from enclosure (FO-7).
b. Installation
(1) Run the AC adapter wires through enclosure cable inlets and connect to TB-1 (2) pins 1 and 2 (FO-7).
(2) Use plastic tie wraps to lace the Ac adapter input wires to panel assembly (8).
(3) Connect AC adapter to power source.
(4) Place front access cover on enclosure and secure.
3-141