REPLACE 12 VDC, 12 POINTS, INTERIOR SUB-RADC (LEDA) WITH POWER SUPPLY
REPLACE LEDA FLEX TERMINATION PWA

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  213    214    215    216    217  218  219    220    221    222    223  
img
. . .
TM 5-6350-275-24&P
3-62. REPLACE 12 VDC, 12 POINTS, INTERIOR SUB-RADC (LEDA) WITH POWER
SUPPLY. (See Figure 3-41). (continued)
(6) Connect the three input power cord leads to input power terminal (24) and secure using a flat tip
screwdriver.
(7) Reconnect input power.
(8) Replace enclosure cover and secure.
3-63. REPLACE LEDA FLEX PWA.
(See Figure 3-41).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on equipment.
Enclosure access cover removed
Materials/Parts:
Wear ESD wriststrap while working on equipment.
Leda Flex PWA
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Remove slip-on terminal strip from TB-7 (3).
(2) Remove ribbon cable (4) from connector P1.
(3) Press out on side of snap track PWA holder (e) and remove the Leda Flex PWA (2).
(4) Place the removed PWA into an ESD protective bag.
b. Installation
(1) Set the link settings and/or switch settings exactly the same as removed PWA or refer to Appendix E, page
E-44.
(2) Press out on side of snap track PWA holder (e) and install Leda Flex PWA (2) in snap track alignment slots
and release.
(3) Connect ribbon cable (4) to connector P1.
(4) Connect slip-on terminal strip to TB-7 (3).
(5) Reconnect input power.
(6) Replace enclosure cover and secure.