REPLACE 18 VAC ADAPTER. (Figure 3-40 and FO-7).
REPLACE RADC ENCLOSURE TAMPER SWITCH. (Figure 3-40).

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  209    210    211    212    213  214  215    216    217    218    219  
img
.
TM 5-6350-275-24&P
3-60. REPLACE 12 VDC BATTERY. (Figure 3-40).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Enclosure cover removed
Remove all jewelry while working on equipment.
Materials/Parts:
12 VDC battery
Wear ESD wriststrap while
working on equipment.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Remove red and black wires slip-on terminal lugs from positive and negative terminals (26) of 12 vdc
battery (25).
(2) Remove battery from enclosure.
b. Installation
(1) Place the 12 vdc battery (25) in enclosure.
(2) Connect red and black wires slip-on terminal lugs to positive and negative terminals (26) of 12 vdc battery
(25).
(3) Connect AC adapter to power source.
(4) Place front access cover on enclosure and secure.
3-142