TM 5-6350-275-24&P
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Tools:
Equipment Condition:
Screwdriver, Flat tip (Item 6, App B)
AC adapter disconnected
General Safety Instructions:
Materials/Parts:
Remove all jewelry while working on
18 vac adapter
equipment.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Open and remove front access cover from NEMA 4 enclosure.
(2) Remove ac adapter (12) from ac outlet power receptacle (7).
(3) Disconnect adapter wires from Stargate 1000 PWA (10) TB1 pins 1 and 2.
(4) Remove ac adapter (12) from RADC enclosure.
b. Installation
(1) Place ac adapter (12) in RADC enclosure.
(2) Connect ac adapter two input wires to Stargate 1000 PWA (10) TB1 pins 1 and 2.
(3) Plug in ac adapter (12) to ac outlet power receptacle (7).
(4) Place front access cover on NEMA 4 enclosure and secure it.