REPLACE 12 V BATTERY.(Exterior) (Figure 3-39).
Figure 3-39. Removal and Replacement of Exterior RADC Assemblies

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  202    203    204    205    206  207  208    209    210    211    212  
img
. .
TM 5-6350-275-24&P
3-55. REPLACE TAMPER SWITCH.(Exterior) (See Figure 3-39).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working
Enclosure access cover removed
on equipment.
Tools:
Wear ESD wriststrap while
Flat tip screwdriver (Item 6, App B)
working on equipment.
Materials/Parts:
Tamper switch
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Replace
(1) Tag and remove the two slip-on connectors (14) from Tamper Switch (13), by holding and pulling out on
connectors.
(2) Using a flat tip screwdriver, remove the two screws (16) and flat washers (15) holding and Tamper Switch
(13) to enclosure.
(3) Remove Tamper Switch from enclosure.
b. Installation
(1) Align Tamper Switch up with enclosure mount and secure with two screws (16) and flat washers (15).
(2) Connect the tagged wires and connectors (14) to Tamper Switch (13).
(3) Connect AC adapter to power source.
(4) Replace enclosure cover and secure.