Table 5-1. Direct Support Troubleshooting - Continued
Figure 5-2. Test Set, Louver Removal

Test Set, Electrical (0-33Kw Load Bank) Model 1057 Page Navigation
  16    17    18    19    20  21  22    23    24    25    26  
img
. . .
TM5-6625-2694-13&P
Section
III.
MAINTENANCE
OF
MAIN
HOUSING
ASSEMBLY
5-5. Test Set Louver (Figure 5-2).
a. Remove
b. Inspect
c. Repair
d. Install
INITIAL SET-UP
personnel Required: MOS 52D10
Tools and Equipment:
MOS 44B
Equipment Condition: Power Off
Electrical Repair Tool Kit
(4940-00-294-9517)
Rivet Kit (5120-00-017-2849)
REMARKS
ACTION
LOCATION
ITEM
REMOVE
Remove Louver
1.
Loosen
Four screws (1)
Louver (2)
INSPECT
2.
Inspect For:
Louver (2)
Cracked Welds,
Louver Damage,
Air Blockage,
Faulty Fasteners.
REPAIR
3.
Weld Cracks, Straight-
If Beyond
Louver (2)
en Louvers, Remove Air
Repair, Re-
Blockage, Repair
place Louver
Faulty Fasteners
INSTALL
4.
Louver (2)
Louver
a.
Install
Tighten
b.
Four screws
(1)
Change