TM 5-6350-275-24&P
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
General Safety Instructions:
Materials/Parts:
Remove all jewelry while working on
CCTV Video Sync Amplifier
equipment.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Removal
(1) Turn off video sync amplifier (2) main power off/on switch (1).
(2) Remove ac power cord (3) from power source.
(3) Tag and remove all coaxial cables from rear panel (4) coax connector jacks.
b. Installation
(1) Connect all tagged coaxial cables to rear panel (4) coax connector jacks.
(2) Connect ac power cord (3) to power source.
(3) Turn on video sync amplifier (2) main power off/on switch (1).
3-195