Figure 3-51. Removal and Replacement of CCTV Camera and Indoor Housing Assembly (TC9353)
Figure 3-52. Removal and Replacement of CCTV Sync Generator

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  260    261    262    263    264  265  266    267    268    269    270  
img
.
TM 5-6350-275-24&P
3-100. REPLACE CCTV SYNC GENERATOR. (Figure 3-52).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
General Safety Instructions:
Materials/Parts:
Remove all jewelry while working on
CCTV Sync Generator
equipment.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables. Failure to do so may result in
serious injury or death.
a. Removal
(1) Remove ac power cord (2) from power source and color sync generator (1) power input connector (4).
(2) Tag and disconnect all coaxial cables from color sync generator (1) coaxial connectors (3).
b. Installation
(1) Connect all tagged coaxial cables to color sync generator (1) coaxial connectors (3).
(2) Connect ac power cord to color sync generator (1) power input connector and to ac power receptacle.