REPLACE TAMPER SWITCH.(Interior) (see Figure 3-38).
Figure 3-38. Removal and Replacement of interior RADC Assemblies

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  192    193    194    195    196  197  198    199    200    201    202  
img
. .
TM 5-6350-275-24&P
3-46. REPLACE 20 VDC POWER SUPPLY. (See Figure 3-38).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
General Safety Instructions:
Screwdriver, Flat tip (Item 6, App B)
Remove all jewelry while working on
equipment.
Equipment Condition:
Input power removed
Wear ESD wriststrap while handling electronic
assemblies.
Materials/Parts:
20 VDC Power Supply PWA
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables. Failure to do
so may result in serious injury or death.
a. Removal
(1)
Tag and remove wires from 20 vdc power supply (8), TB-1, pins 1 through 6.
(2)
Press out on side of snap track assembly holder (12) and remove the 20 vdc power supply (8).
a. Installation
(1)
Press out on side of snap track assembly holder (12) and install 20 vdc power supply (8) in snap track
alignment slots and release.
(2)
Connect the tagged wires to TB-1, pins 1 through 6.
(3)
Reconnect the input power to RADC Assembly.
(4)
Replace enclosure cover and secure.
3-125