REPLACE LEDA FLEX TERMINATION CARD ASSEMBLY. (Interior) (Figure 3-38 and FO-4).
REPLACE TAMPER SWITCH.(Interior) (see Figure 3-38).

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  190    191    192    193    194  195  196    197    198    199    200  
img
. .
TM 5-6350-275-24&P
3-44. REPLACE 12 V BATTERY. (Interior) (Figure 3-38).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
General Safety Instructions:
Screwdriver, Flat tip (Item 6, App B)
Remove all jewelry while working on
equipment.
Equipment Condition:
AC adapter disconnected
Wear ESD wriststrap while handling electronic
assemblies.
Materials/Parts:
Battery, 12 vdc, 7 AH
a. Removal
(1)
Open and remove front access cover from enclosure.
(2)
Remove red and black slip-on terminal lugs from positive and negative terminals of 12 v battery (9).
(3)
Remove battery from enclosure.
b. Installation
(1)
Place 12 v battery (9) in enclosure.
(2)
Connect red and black slip-on terminal lugs to positive and negative terminals of 12 v battery.
(3)
Connect AC adapter to power source.
(4)
Place front access cover on enclosure and secure it.
3-123