REPLACE MOD II MODEM PWA. (Interior) (Figure 3-38).
REPLACE 12 V BATTERY. (Interior) (Figure 3-38).

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  189    190    191    192    193  194  195    196    197    198    199  
img
. . . . . .
TM 5-6350-275-24&P
3-43. REPLACE LEDA FLEX TERMINATION CARD ASSEMBLY. (Interior) (Figure 3-38 and FO-4).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
General Safety Instructions:
Screwdriver, Flat tip (Item 6, App B)
Remove all jewelry while working on
equipment.
Equipment Condition:
AC adapter disconnected
Wear ESD wriststrap while handling electronic
assemblies.
Materials/Parts:
Leda Flex Termination Card PWA
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables. Failure to do
so may result in serious injury or death.
a. Removal
(1)
Open and remove front access cover from enclosure.
(2)
Tag and remove slip-on terminal strip from TB1 through TB8 (FO-4 sheet 4) on PWA (1).
(3)
Remove ribbon cable from connector PL1 (29) on PWA (1).
(4)
Press out on sides of snap track PWA holder (12) and remove PWA (1).
b. Installation
(1)
Set link settings and/or switch settings exactly the same as removed PWA or refer to Appendix E, page E-46.
(2)
Press out on sides of snap track (12) PWA holder and install PWA (1) in snap track alignment slots.
(3)
Connect ribbon cable to connector PL1 (29).
(4)
Connect tagged wires to TB1 through TB8 (FO-4 sheet 4).
(5)
Connect AC adapter to power source.
(6)
Place front access cover on enclosure and secure it.