TM 5-6350-264-14&P-12
NAVELEX EE 181-AA-OM1-120/E121 C-7359-60-1
TO 31S9-2FSS9-1-12
Table 5-1. Troubleshooting Procedures - Continued
Probable cause
Trouble
Corrective action
1. (cont)
g. (cont)
h. If this indication is not correct, re-
place Data Transmitter.
i. Connect meter leads between ter-
minal E27 and ground (aluminum
baseplate). Meter should indicate
over 100,000 ohms.
j. If this indication is not correct, re-
place Data Transmitter.
k. Connect negative meter lead to post
terminal E25 and positive lead to
E24. Meter should indicate 500 to
6,500 ohms. Reverse leads. Connect
negative meter lead to E24 and posi-
tive lead to E25. Meter should indi-
cate 5,000 to 65,000 ohms.
l. If either of these indications is not
m. Connect negative meter lead to post
terminal E28 and positive meter
lead to E24. Meter should indicate
500 to 6,500 ohms. Reverse leads.
Connect negative meter lead to
E24 and positive lead to E28.
Meter should indicate 5,000 to
65,000 ohms.
n. If either of these indications is not
o. Connect negative meter lead to post
terminal E29 and positive meter lead
to E32. Meter should indicate 500
to 6,500 ohms. Reverse leads. Con-
nect negative meter lead to E32
and positive lead to E29. Meter
should indicate 5,000 to 65,000
ohms.
p. If either of these indications is not
q. Connect negative meter lead to
post terminal E30 and positive
meter lead to E32. Meter should
5-16