TM 11-6625-2884-30/NAVAIR 16-35TS3615-2
SECTION Ill
TROUBLESHOOTING
PAGE
SECTION CONTENTS
GENERAL
TEST CONDITIONS
DEFINITIONS
TEST EQUIPMENT USE
PRELIMINARY TEST SET-UP
RF OUTPUT LEVEL CHECK
RF OUTPUT FREQUENCY CHECK
VARIABLE PRI CHECK
CON SCAN MODULATION CHECK
PRI CHECK
BLANKING OUTPUT TEST
PULSE SYNC TEST
CON SCAN SYNC TEST
STATUS PANEL INDICATOR CHECK
STATUS PANEL FORCING FUNCTION CHECK
STATUS PANEL OSCILLOSCOPE MONITOR CHECK
STATUS PANEL VOLTAGE MONITOR CHECK
YIG FILTER CHECK
CONTROL PANEL CHECK
GENERAL
3-10. Troubleshooting information is covered in paragraphs 3-15 through 3-28.
Each paragraph provides the test set-up and contains tests in tabular logic
tree format consisting of four staggered columns. Column 1 contains STEP
numbers with the steps in ascending order. Column 2 designated ACTION explains
the test. Column 3 NORMAL INDICATION states what measurements should be
observed for normal circuit operation. Column 4 designated FIX lists what
course to follow if a measurement deviates excessively from the stated value in
column 3.
3-7
|