TIM 11-6625-2884-30/NAVAIR 16-35TS3615-2
STATUS
PANEL
OSCILLOSCOPE
MONITOR
CHECK
3-25.
a.
Test Equipment.
Oscilloscope AN/USM-281A
Digital Multimeter AN/USM-451
b.
Test Connections and Conditions.
( 1 ) Connect oscilloscope external sync jack to 1A3 SYNC CS jack.
(2) Connect oscilloscope vertical input jack to 1A2 CHAN 2 jack.
c.
Initial Test Equipment Setting.
(1) Set sweep speed to 5 ms/DIV.
(2) Other controls are as in paragraph 3-14a.
3-55
|