TM 11-6625-2884-30/NAVAIR 16-35TS3615-2
VARIABLE PRI CHECK
3-17.
Test Equipment.
a.
AN/USM-218A
Oscilloscope
b.
Test Connections and Conditions.
Connect RF Cable W5 from 1A3 RF OUT jack to 1A2 RF IN jack.
1.
2.
Connect Video cable W1O from Status Panel 1A2 CHAN 1 to oscillo-
scope vertical input jack.
3.
Connect Video cable W1O from RF Modulation Assembly 1A3 SYNC PULSE
to oscilloscope external sync jack.
c. Initial Test Equipment Setting. Set oscilloscope sensitivity to 0.1 V/DIV.
Other equipment settings are as in paragraph 3-14a.