CAUTION
The following paragraphs assume that the BTS is
instal1ed per appropriate instructions, para-
graph 3-6 through paragraph 3-8, of this
manual .  Note particularly the caution in
paragraph 3-6 and instructions of paragraph 3-7
relating to top cover.
a. Press any of the circuit breakers discussed in the preceding note if a
white side surface is showing.
CAUTION
A visible white side surface on a circuit breaker
may indicate a fault in the panel assembly. If
the circuit breaker does not hold, refer to higher
level of maintenance.
b.  Energize the BTS ac power by setting POWER 115 VAC 60 Hz 1 circuit
breaker on the CONTROL PANEL ASSEMBLY 1A1 to ON.