-7-
(o) The preceding tests and adjustments must be successfully
performed to assure proper operation of the actuator test stand.
2-4 ACTUATOR TEST
(a) Remove calibration manifold and install actuator to be
Connect supply line and G3 to "P" through the swivel nut
tested.
tee, return tube to "R", G1 to A1, G2 to A2 and cables W3 and W4 to
(See Figure 2).
actuator connectors.
(b)
Determine the style number of the actuator being tested
and refer to the appropriate table for test pressures and meter
readings.
(c)
Set S2 at ON.
(d)
Starting with S3 in START position rotate S3 to each of
the other four positions and compare all meter and gauge readings
with the values specified in the table.
(e) Turn the pump (S2) off and return S3 to start position.
(f) Refer to the appropriate table and determine the
Manually place the piston
actuator piston position for full fuel.
in the full fuel position and Meter M1 should read less than 20 volts.
(g) Move the piston gradually towards the fully closed
throttle position, the transducer secondary voltage indicated on
Meter M1 should increase in a linear manner to a maximum of more than
20 volts.
(h) Slowly move the actuator piston from no fuel to full
fuel position and M1 should steadily decrease without changing
direction of movement.
If the results obtained during the above tests do not meet
the specifications, the actuator requires adjustment or repair.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |