TM 55-4920-415-13&P
Observe the glass window, oil level indicator to
b. Remove the oil plug (11, Figure 1-1) and fill the
check the proper amount.
gear box with suitable oil given in Table 3-1.
.
SECTION III. PREVENTATIVE MAINTENANCE
3-7. Services Performed by the Operator.
These
services are performed on a daily basis.
Table 3-2: Daily Services
Prior to
During
Securing
Operation
Operation
Unit
Service
X
X
-
Indicator Lights - Inspect them.
Replace the fuse or lamp as necessary.
X
X
X
Oil Leaks - Inspect the gear box for oil
leaks.
X
-
X
Oil Level - Check the oil level.
Make sure the type meets the temperature
requirements.
-
-
X
Cleaning - Use a cloth moistened with an
approved solvent to clean the gyro tester.
3-8. Services Performed at Six Month Intervals
Table 3-3: Six Month Services
Inspection
Functional
Service
X
-
Visual Inspection - Check the unit overall for loose, missing,
or broken parts. Make sure the unit is correctly assembled.
Correct any deficiencies before placing unit in operation.
X
-
Electrical Wiring - Check the unit for loose or bare wires or
corroded connections. Replace the defective wiring. Use a
fine sandpaper to clean connector terminals.
X
-
Prior to Operation - Perform the services listed in Table 3-2.
prior to operation.
-
X
Fork Rotation Speed - Check the rotational rate of the fork
with the use of a stop watch against the nominal setting
given on the rotational rate switch (26, Figure 2-1.), Paragraph
3-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |