TM 5-6350-275-24&P
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
General Safety Instructions:
Screwdriver, Cross tip (Item 5, App B)
Remove all jewelry while working on
Screwdriver, Flat tip (Item 7, App B)
equipment.
Materials/Parts:
Vibration Sensor
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Removal
(1) Remove power to primary power source.
(2) Remove two screws (3) holding front face plate (4) on sensor housing (5).
(3) Tag and remove wiring from TB1 (6) on sensor board.
(4) Remove three screws (7) holding sensor to back mounting plate (8) and remove sensor from
housing.
b. Installation
(1) Align sensor (5) with back housing (8) and secure with three screws (7).
(2) Connect tagged wiring to sensor board TB1 (6).
(3) Align front plate (4) with sensor housing (5) and secure with two flat head screws (3).
(4) Apply power to primary power source.
(5) Set sensitive adjustment. Ref. (SAIG, Appendix E, Section 6).
3-237