3-127. REPLACE TAUT WIRE 90 FENCE SENSOR. (Figure 3-72).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
Equipment Condition:
Opened wrench set (Item 13, App. B)
Access Cover Open
Wire cutters (Item 24, App. B)
Wire strippers (Item 10, App. B)
General Safety Instructions:
Soldering iron (Item 39, App. B)
Remove all jewelry while working on
equipment.
Materials/Parts:
Heat shrink tubing (Item 14, App. D)
Taut Wire 90 Sensor Post Assembly
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Removal
(1) For DTR-90 sensor assembly (1), tag and unsolder wire connections (2).
(2) Loosen barb wire mounting bolt (3) and remove wire.
(3) Loosen mounting bolt (4).
(4) Remove sensor assembly (1) from sensor post.
b. Installation
(1) Replace sensor assembly (1) to inside sensor post.
(2) Tighten mounting bolt (4).
(3) Slip heat shrink tubing onto wire.
(4) Solder wire connections.
(5) Shrink heat shrink tubing to size.
(6) Install barb wire and tighten mounting bolt (3).
(7) Set sensitive adjustment. Ref. (SAIG, Appendix E, Section 13).