Figure 3-70. Removal and Replacement of Strain Sensitive Cable Sensor (Processor) PWA
REPLACE STRAIN-SENSITIVE CABLE FENCE SENSOR, JUNCTION SPLICE ASSEMBLY, OR TERMINATION ASSEMBLY. - Continued

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  298    299    300    301    302  303  304    305    306    307    308  
img
. . . . . . . . .
TM 5-6350-275-24&P
3-126. REPLACE STRAIN-SENSITIVE CABLE FENCE SENSOR, JUNCTION SPLICE
ASSEMBLY, OR TERMINATION ASSEMBLY. (Figure 3-71 and 3-70).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
Test Equipment:
Screwdriver, Cross tip (Item 5, App B)
Digital Multimeter
Screwdriver, Flat tip (Item 7, App B)
Open End Wrench Set (Item 13, App B)
General Safety Instructions:
Wire Cutters (Item 24, App B)
Remove all jewelry while working on
Wire Strippers (Item 10, App B)
equipment.
Materials/Parts:
Junction Splice Assembly
Terminator Assembly
Tie Wraps (Item 13, App D)
a. Removal
(1) Disconnect coaxial cables (6) at cable inputs 1 and 2 connectors on processor assembly. (Figure 3-70)
(2) Using diagonal cutting pliers, cut coaxial cables (6) (Figure 3-71) as close to retainer cap (5) as possible.
(3) Using diagonal cutting pliers, cut tie wrap (1) and remove junction splice assembly (2) or terminator assembly
(11) from fence.
b. Installation
(1) Remove knockout hole from retainer cap (5).
(2) Insert both cables or cable through cap holes (larger holes for insensitive cable).
(3) With a wire stripper, strip back outer insulation of coaxial cable(s) (6) approximately 1 inch (26 mm).
(4) Cut and fold braided shields (7) back over outer insulation by 0.25 inch.
(5) Strip center conductor insulation (8) to 0.5 inches (13 mm).
(6) Remove PWA (10) shield retainer (4).
(7) Wrap center conductor wires (9) CW around upper screws (3) of splice PWA (10).
(8) Tighten both screws using a No. 3 phillips head screwdriver.
(9) Cut off and discard excess braid and center conductor wire.
(10) Push PWA (10) far enough into terminator housing (2) so black outer insulation of cables is well inside
housing.
(11) Test cables for shorts and opens with a digital voltmeter.
3-231