REPLACE CLOSED CIRCUIT TV CAMERA 2/3 IN. (EXTERIOR)

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  254    255    256    257    258  259  260    261    262    263    264  
img
. .
TM 5-6350-275-24&P
3-96. REPLACE CLOSED CIRCUIT TV CAMERA 1/2 IN. (INTERIOR). (Figure 3-49).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
General Safety Instructions:
Open End Wrench Set (Item 13, App B)
Remove all jewelry while working on
equipment.
Materials/Parts:
CCTV Camera 1/2" (Interior)
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Removal
(1) Unplug ac power cord (5) from power source.
(2) Remove coaxial cable(s) from Sync In connector (3) and Video output connector (4).
(3) Remove 1/4 in. bolt (2) and mounting hardware from top or bottom of camera housing and mounting bracket
and remove camera (1) from mounting bracket.
b. Installation
(1) Place camera onto mounting bracket and remount using 1/4 in. bolt and mounting hardware.
(2) Connect coaxial cable(s) to Sync In connector (3) and Video output connector (4).
(3) Connect ac power cord (5) to power source.