Click here to make tpub.com your Home Page

Page Title: OPERATING PROCEDURES
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-6625-3024-14/EE641-AC-MMA-010/E154 SYSEX/TO 33AA50-5-1-1
3-3. OPERATING PROCEDURES
Note
The Exerciser is in standby when
Operating procedures for the Exerciser assume
the following indicators are lit: BOT,
that Installation and Preparation for Use, as de-
READY, SELECTED, WRITE EN-
fined in Section II of this manual, have been com-
ABLE, WRITE RESET, one MO-
pleted. It also assumes that the transport is func-
TION CONTROL-SELECT indica-
tioning properly. These procedures include all steps
tor, POWER ON OFF ECR-10
necessary to bring the Exerciser from OFF through
460-9101,
ECR-10 460-9101,
standby to full operation, and from full operation
SYSTEM ON OFF and STOP. Also
through standby to OFF.
the PARITY ERRORS HARD and
SOFT displays must be zeroes.
The operating procedure will vary according to
the user's requirements, The following is a general
Perform all or any of the following steps neces-
operating procedure  intended to inform the
sary to bring the Exerciser to standby:
operator of the general method of operating the
Exerciser.
1. Press SYSTEM ON/OFF switch to apply
power to the Exerciser.
CAUTION
2. Verify that only the SYSTEM ON/OFF indi-
cator, WRITE RESET indicator and STOP indi-
Do not turn on power without first
cator are lit. Ignore WRITE DATA indicators. If
checking to ensure that no indica-
the STOP indicator is not lit, intermittently de-
tor lamps are missing from socket.
press PROCESSOR RESET until it does light.
Burnout of transistor driver will oc-
cur if lamp is missing, Refer to par-
3. Press PARITY ERRORS-RESET switch.
agraph 5-12 for replacement.
Verify that SOFT ERROR and HARD ERROR
displays are reset to zero.
Note
4. Verify that all cable connections are made to
All switch indicators are push-ON and
the transport. See Figure 2-1. Verify that a car-
push-OFF pushbutton switches. When
tridge which is write enabled is installed in the
the indicator is lit, the function is en-
transport.
abled (ON),
5, Verify that the current sense loop or am-
meter is in place.
Note
6. Press TRANSPORT-ECR-10 460-9101 switch
to apply power to the transport.
Before operating, press the LAMP TEST
switch located on the top connector panel,
7. Verify that the TRANSPORT ECR-10 460-
Verify that all indicators light except TRANS-
9101 indicator is lit.
PORT power switch (located above SYS-
TEM ON OFF switch) and the nine write
8. Observe address position selected on trans-
data Indicator switches.
port and press corresponding MOTION CONTROL
select switch (SELECT 1 through SELECT 4) on
Exerciser. Verify that select switch selected indi-
3-4. STANDBY MODE
cator lights.
The Exerciser should be in the Standby mode
9. Verify that STATUS INDICATOR-READY
prior to performing the functional checks de-
indicator is lit. If indicator is not lit close trans-
scribed in the following paragraphs.
port door.
3-12

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business