TM 11-6625-3024-14/EE641-AC-MMA-010/E154 SYSEX/10 33AA50-5-1-1
10. Verify that STATUS INDICATOR-BOT
Note
indicator is lit. If indicator is not lit, press MOTION
CONTROL-REWIND switch. STATUS lNDlCA-
If tape is allowed to run to EOT,
TION-IN REWIND indicator will Iight and READY
Exerciser will automatically rewind the
indicator will extinguish while tape is in rewind
tape to BOT.
motion.
6. Press DATA CONTROL-WRITE switch.
Note
Verify that indicator extinguishes.
Transport motion cannot be inter-
7. Press REWIND.
rupted while tape cartridge is rewinding
(IN REWIND indicator lit).
3-6. WRITE DATA OPTIONS
When transport tape cartridge has rewound to
beginning-of-tape, the IN REWIND indicator will
The following options are available in the Write
extinguish and the BOT indicator will light.
Data mode. Any one of the options can be selected
in conjunction with the WRITE switch as described
in paragraphs 3-7 through 3-10.
3-5. WRITE DATA MODE
Write Data mode produces continuous or block
3-7. BLOCK MODE
data for recording on the transport tape.
Produces data in 256 byte or 4K byte blocks.
Each block is ended with a CRC (CYCLIC RE-
1. Ensure that Exerciser is in the Standby mode
DUNDANCY CHECK) and LRC word.
(see paragraph 3-4).
1. Ensure that the Exerciser is in the Stand-
2. Select the WRITE DATA to be recorded on
by mode (see paragraph 3-4).
tape. The WRITE DATA SWITCHES (PAT. /0/1)
provide individual track selection of data. All
2. Set the DATA CONTROL switches as
tracks can be set to same data (encluding parity in
follows:
ALL 0) by pressing ALL 0, ALL PAT., or ALL 1
pushbutton switches. The WRITE DATA indi-
- OFF
CONT. READ
cators will light to indicate the type of data selec-
REPEAT ON ERROR
- OFF
ted for each track.
4K BLOCK
- OFF
SHIFT ONES
- OFF
3. Press DATA CONTROL-WRITE switch.
BLOCK MODE
- ON
WRITE
- ON
4. Press MOTION CONTROL-RUN FORWARD
switch. Verify that the STOP and WRITE RESET
3. Press MOTION CONTROL-RUN FORWARD
indicators extinguish and RUN FORWARD indi-
switch. Verify that the STOP indicator extin-
cator lights.
guishes and the RUN FORWARD and WRITE
RESET indicators flicker.
Continuous data will be recorded on transport
tape in this mode. Errors (parity errors) will be
Data will be recorded on transport tape in 256
counted and displayed on the SOFT ERROR
byte blocks. Errors (parity errors) will be counted
digital display while the transport is in write mode.
and displayed on the SOFT ERROR digital dis-
While the transport is in motion, no other control
play. While the transport is in motion, no other
(data or motion) can be changed until the trans-
control (data or motion) can be changed until the
port motion is stopped.
transport is stopped.
5. Press STOP switch to stop transport motion.
4. Press STOP switch to stop transport motion.
Verify that the STOP and WRITE RESET in-
Verify that the STOP indicator lights and the RUN
dicators light and RUN FORWARD indicator
FORWARD indicator extinguishes.
extinguishes.
3-13
|