TM 11-6625-2975-40
2-33. RF MODULATOR ASSEMBLY
A3 AND SYNTHESlZER ASSEMBLY A4 REPLACEMENT. (CONT)
INSTALLATION
NOTE
If assemblies A3 (4) and A4 (5) are separated, perform steps 1, 2, and 3.
1. Aline coaxial connectors and plug connectors on assemblies A3 (4) and A4 (5) and push
together.
2. Install four screws (9), Iockwashers (10), and fiat washers (11).
3. Position top bracket (8) on assemblies (detail A) and install four screws (6) and
Iockwashers (7).
NOTE
When placing assemblies A3 (4) and A4 (5) in chassis as a unit, aline pins on bottom of
assembly A3 with holes in chassis.
4. Install assemblies A3 (4) and A4 (5) in chassis.
5. Connect coaxial connector (2) and connector P5 (3) to assembly A3 (4).
6. Install two screws (1) from each side of chassis.
FOLLOW-ON MAINTENANCE: Install dust cover (para 2-28).