TM 1-6625-735-14
Table 5-2.
Calibration Equipment.
Item
Common Name
Minimum Use
Calibration Equipment*
Specifications
A1
AC Precision Power Sup- Range: 115 vac, N. H. Research Inc. Model
ply
400 Hz
SF613-1
Accuracy: 6 0.5% (MIS-1022, Type 1); K-H
4100/7500A
Range: 0 to 20 vdc Hewlett-Packard, Model
A2
Digital Multimeter
Accuracy:6 0.25 % 3490A Option 060; Dana
Range: 0 to 2 vac Model 5000-52351A
Accuracy: 6 0.25
%
A3
Ratio Transformer
Range: 0.000000 to ESI Model DT-72A
1.000000
Accuracy:6 1 digit
HP3400A,
HP400E,
A4
AC Voltmeter
Range: NA
Indication HP400EL
(Null
Only)
*The calibration equipment utilized in this procedure was selected from those known to be available at Depart-
ment of Defense facilities, and the listing by make or model number carries no implication of preference,
recommendation, or approval by the Department of Defense for use by other agencies. It is recognized that
equivalent produced by other manufacturers may be capable of equally satisfactory performance in the procedure.
Accessories Required.
Item
Common Name
Description
B1
Adapter*
Single banana jack to pin plug
(red) (7907517)
B2
Adapter
Single banana jack to pin plug
(black) (7907528)
B3
Adapter Box
Double banana jack termination
(SKD4850-3)
B4
Lead (test lead)*
24-in., single banana plug termina-
tion (red) (7907497)
B5
Lead (test lead)*
24-in., single banana plug termina-
tion (black) (7907498)
B6
Test Probe*
Single banana to test hook
5-72
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |