(c)
Directional Coil Current
A check that when the proper current is applied
to one coil or the other that the correct hydraulic pressure is
applied to the piston extending or retracting it as determined by
the type of actuator being tested.
(D)
Ancillary Test Circuits
Circuits have been provided to check out the Test
Stand to determine that the actuator test circuits are working and
that they are adjusted properly.
Gauge Pressure Test
(E)
A manifold is included to compare the 0-400 psi
hydraulic gauges to ascertain that they are calibrated.
1-4 PRIMARY POWER REQUIREMENTS
--
The Actuator Test Stand requires an input of 120 volts 10%
60 Hz. 10 amps.
1-5 TEMPERATURE CAPABILITIES
The Actuator Test Stand is capable of proper operation within
the temperature range of + 40F(+4C) to + 125F (+52C) at
altitudes to 10,000 feet.
1-6 DESCRIPTION OF EQUIPMENT
The Hydraulic Actuator Test Stand (Figure 1) consists
essentially of a hydraulic sump, electric motor driven hydraulic
pump, electric controls for actuator coils, bracket to hold
actuator while under tests and associated filters, plumbing,
The equipment operating controls and indicators are
wiring, etc.
located in a control drawer and on the inside of the top cover.