Rectifier Bridge.
Load Switch.

Test Set, Electrical (0-33Kw Load Bank) Model 1057 Page Navigation
  36    37    38    39    40  41  42    43    44    45    46  
img
. . . .
TM5-6625-2694-13&P
5-20.
Circuit
Breaker.
Replace
INITIAL
SET-UP
Tools
and
Equipment:
Personnel
Required:
MOS
52D10
Electrical
Repair
Tool
Kit
Equipment
Condition:
Power
Off
(4940-00-294-9517)
Housing
Removed
(Para.
5-11)
ITEM
LOCATION
ACTION
REPLACE
Breaker(1)
a.
Six
Terminals(2)
Disconnect
and
Tag,
Wires
Pull
Off
b.
Rod(3),
Spacer(7)
Remove
With
Pin
Punch
c.
Six
Screws(4),
Six
Remove
Lock  Washers(5),  Six  Flat
Washers(6)
d.
Breaker(1)
Remove
and
Replace
e.  Six  Flat  Washers(6),
Install
and
Tighten
Six  Lock  Washers(5)
Six
Screws(4)
f.
Rod(3),
Spacers(7)
Insert
Six
Terminals(2)
Remove
Tags
and
Connect
g.
h.
Housing
Install
(Para.
5-11)
5-29