Contactor
Control Relay.

Test Set, Electrical (0-33Kw Load Bank) Model 1057 Page Navigation
  30    31    32    33    34  35  36    37    38    39    40  
img
. . . .
TM5-6625-2694-13&P
5-13.
Contactor
Relay.
Replace
INITIAL
SET-UP
Tools
and
Equipment:
Personnel
Required:
MOS
52D10
Equipment
Condition:
Power
Off
Electrical
Repair
Tool
Kit
Housing
Removed
(Para.
5-11)
(4940-00-294-9517)
ACTION
ITEM
LOCATION
REPLACE
RELAY(1)
Remove
and
Tag
Wires
a.  Four  Screws(2)
Four  Wires(7)
Remove
b.  TWO  Nuts(6),  Two  Lock
Washers(5),  Four  Flat
Washers(4),  Two  Screws(3)
Remove
and
Replace
c.
Relay(1)
Install
and
Tighten
d.  Two  Screws(3),  Four
Flat  Washers(4),  Two  Lock
Washers(5),  Two  Nuts(6)
Remove  Tags,
Install
and
e.  Four  Screws(2)
Four  Wires(7)
Tighten
Install
(Para.
5-11)
f.
Housing