Table 3-2. Primary Monitor Console DS Maintenance Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
High voltage exists inside the printer assembly. Be careful while making voltage checks, and remove
power while replacing assemblies. Otherwise serious injury or death may occur, and serious damage to
the equipment may occur.
Step 1. Check the power indication on the printer front panel assembly. The lamp should be on.
If power on lamp is off, remove the input power cable and check for 120 vac at the input receptacle.
If the power on lamp is on, replace the serial interface cable (Para. 3-24).
If printer still does not print, replace the serial interface PWA (Para. 3-25).
If the printer still does not print, replace the printer assembly (Para. 3-24).
If printer still does not print, replace the B38 or B39 CPU (Para. 3-19 or 3-10).