REPLACE LOG PRINTER ASSEMBLY. (Figure 3-30).
Figure 3-32. Printer Serial Interface Printed Wiring Assembly

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  164    165    166    167    168  169  170    171    172    173    174  
img
. .
TM 5-6350-275-24&P
3-25. REPLACE PRINTER SERIAL INTERFACE PWA. (Figure 3-32).
This task consists of:
a. Remove
b. Install
INITIAL SETUP:
Tools:
General Safety Instructions:
Screwdriver, Flat tip (Item 6, App B)
Remove all jewelry while working on
equipment.
Materials/Parts:
Serial Interface Board PWA AP1337-SI
Wear ESD wriststrap while working on
electronic assemblies.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables. Failure to do
so may result in serious injury or death.
a. Removal
(1)
Place printer (1) power on/off switch (2) to off.
(2)
Disconnect ac power cable (3) from AC power source and printer (1).
(3)
Loosen two captive screws (6) holding serial interface cable (7) to serial interface PWA (5).
(4)
Pull down on serial interface PWA holding pen (4) and remove serial interface PWA (5) from printer (1).
b. Installation
(1)
Install serial interface PWA (5) into printer (1) and secure with PWA holding pen (4).
(2)
Connect and secure printer interface cable (7) to serial interface PWA (5) by tightening two captive screws (6).
(3)
Connect ac power cable (3) to printer (1) and AC power source.
(4)
Place printer (1) power on/off switch (2) to on.
3-97