C1, TM 11-6625-646-15
SECTION IV
OPERATING INSTRUCTIONS
tested, connect adapter 114V3058-1 between the test
4-1. General
set J60 SAS receptacle and test cable A02VS309-1.
4-2. This section contains operating instructions for the
test set. Functions and descriptions of the controls,
4-6. SAS Amplifier Testing Procedures
indicators, and receptacles are given in tables 4-1, 4-2,
and 4-3. Numbers in parentheses refer to items on
4-7. To test a SAS amplifier, perform the preliminary
procedures in paragraph 4-4. Then proceed as directed
these components to the schematic diagrams, figures 1-
in the paragraphs that follow. The results of some SAS
amplifier tests are not included in this manual since the
test set. Aircraft Displacement Simulator AN/ASM-120
information is not the same for all models and certain
or equivalent, having an operating range of 1.5 to 18
values are subject to change. For this information, refer
per second is required for yaw, roll, and pitch channel
to TM 11-1680-201-35. Some results not included are
tests on SAS amplifiers. A multimeter, TS-352/U or
the following:
equivalent, and a capacitance, inductance, resistance
a. Test voltages not directly related to power
bridge, AN/URM-90 or equivalent, are also required for
voltage levels.
calibration card tests.
b. Amplifier positioning and channel rate of turn
tests which require the use of the rate table.
4-3. SAS Component Tests
c. Channel output during open and closed loop
testing.
4-4. Preliminary Procedures
d. Test airspeed and test sideslip pressures.
e. Yaw channel output during airspeed and sideslip
channel tests.
circuit board as follows:
a. Release the turnlock fasteners and open the
4-8. Channel Tests Using a Rate Table
hinged door in the test set cover.
Check channel response to rate gyro signals as follows:
b. Set the POWER and PUMP switches to off
a. Check that the ASE MODE switch is at OFF.
(down) positions.
Check that the FUNCTION switch is at DC. Check that
c. Remove the test cables and hose assemblies
the AXES METERS READ switch is at CLOSED LOOP.
from the test set cover. Remove the adapter assembly
Check that the PEDAL POT variable resistor is in the
from the -8 test set.
center of its operating range (straight up).
d. Connect power cable A02VS309-3 between the
b. Position the SAS amplifier on the rate table so it
115V 400 ~ test set receptacle and a 115-volt 400-cycle
turns about the sensitive axis of the channel being
ac source.
tested.
e. Connect test cable A02VS309-1 between the
test set J60 SAS receptacle and the SAS amplifier
receptacle. If SAS amplifier 114E3030-49 is being
27
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |