|
|
TM 11-6625-3056-12
4-6.
MONTHLY PREVENTIVE MAINTENANCE (cont)
Item
Item To Be
No.
Inspected
Procedure
8.
Long
Set controls as follows:
Pattern
Correlator
PATTERN
LONG
Loop
OPERATION
Keep at 4W
CORRELATOR LOOP
OPEN
DATA ON/OFF
Keep at ON
RATE SELECT
Keep at 0 (38.4 kb/s)
DISPLAY SELECT
Keep at ERRORS
Keep DATA OUT connected to DATA IN.
Press RESET:
Display must read 0.
Press SINGLE ERROR several times:
Display must advance one count each time SINGLE ERROR is pressed.
Set CORRELATOR LOOP to CLOSED and press RESET:
Display must read 0.
Press SINGLE ERROR several times:
Display must advance one count each time SINGLE ERROR is pressed.
4-6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |