TM 11-6625-3056-12
4-6.
MONTHLY PREVENTIVE MAINTENANCE (cont)
Item
Item To Be
No.
Inspected
Procedure
Set RATE SELECT to positions 2 thru 7:
ACTIVITY indicator must remain lit at each position of RATE SELECT (except 0).
7.
Short
Control settings:
Pattern
Correlator
PATTERN
Keep at SHORT
Loop
OPERATION
Keep at 4W
CORRELATOR LOOP
Keep at OPEN
DATA ON/OFF
Keep at ON
RATE SELECT
Keep at O (38.4 kb/s)
DISPLAY SELECT
ERRORS
Keep DATA OUT connected to DATA IN.
Press RESET:
Display must read 0.
Press SINGLE ERROR several times:
Display must advance one count each time SINGLE ERROR is pressed.
Set CORRELATOR LOOP to CLOSED and press RESET:
Display must read 0.
Press SINGLE ERROR several times:
Display must advance one count each time SINGLE ERROR is pressed.
4-5
|