2-20. AM MODULATION ADJUSTMENT.
TEST EQUIPMENT REQUIRED: Adapter, N plug-to-BNC jack
Modulation Analyzer HP 8901
RF Cable RG-58/U
EQUIPMENT SETUP Connect test set to 115 vac power source.
Connect modulation analyzer to test set as indicated in the following diagram.
EL9LY021
Turn on equipment. Allow at least 30 minutes for warmup.
PROCEDURE
1. Enter frequency 110.10 MHz into test set.
2. Extinguish 150 Hz TONE SELECT key.
NOTE
90 Hz TONE SELECT key remains lit.
3. Press (to light) % MOD FUNCTION/CONTROL key.
NOTE
RDL/DDM/MOD key indicates 20.0 MOD (%).
4. Reduce RF LEVEL to -6 dBmW.
P/O A3/A4 ASSEMBLY TOP BRACKET
EL9LY030