TM 11-6625-2975-12
OPERATING PROCEDURES. (CONT)
24.
EL9LX042
NOTE
The following step slews DDM, from a .000 reading, in U/L (150 Hz) direction in
continuous 0.001 increments in Iocalizer mode and 0.002 increments in glide slope
mode.
9. 9. Press hold
key.
NOTE
RDL/DDM/MOD display shows an increasing DDM.
DDM can be stewed in this direction to a maximum of 0.400 in Iocalizer mode and 0.800
in glide slope mode.
Release
key.
10.
Using STEP D RDL D DDM key, step to DDM value of .000.
11.
NOTE
The following step slews DDM, from a .000 reading, in D/R (90 Hz) direction, in
continuous 0.001 increments in Iocalizer mode and 0.002 increments in glide slope
mode.
Press and hold
key.
12.
NOTE
RDL/DDM/MOD display shows a decreasing DDM, and D/R (90 Hz) indicator is lit.
DDM can be slewed in this direction to a maximum of 0.400 in Iocalizer mode and 0.800
in glide slope mode.
2-34
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |