TM 11-6625-2975-12
2-4.
OPERATING PROCEDURES. (CONT)
Release
key.
13.
14.
Press STD key once.
15.
Repeat steps 1 through 12 for other rf carrier frequencies.
DDM BALANCE CHECK ADJUSTMENTS
EL9LX043
NOTE
The following procedure is typical for discussion of test set operation and can be varied
as required during actual receiver testing.
The following procedure applies to Iocalizer and glide slope modes only.
1. Using STEP D RDL D DDM key, enter standard DDM of .046.
NOTE
If RDL/DDM/MOD display flashes on and off, press and hold CLEAR key until display
stops flashing. Then, repeat step 1 and enter correct DDM.
If DDM step has been entered correctly, RDL/DDM/MOD display will show .046.
U/L (150 Hz) indicator is lit to indicate direction DDM will go when DDM is changed using
STEP D RDL D DDM key, slewing keys, on DATA ENTRY keys.
2-35