TM 11-6625-2937-13
Figure 5-2. Control-interface unit, waveforms.
troubleshooting table for the digital tester.
5-8.
Digital Tester Troubleshooting
Refer to TM I 1-6625-2951-13 for the test procedure and
Section IV. MAINTENANCE OF TEST SET, ELECTRONIC SYSTEMS AN/UKM4
the digital tester.
5-9.
General
5-10. Power Supply Al PSI Adjustment
This section contains  direct support maintenance
a. Tools and Test Equipment Required. The
procedures for adjusting the power supplies in the
control interface unit. Direct support maintenance of the
following tools and test equipment are required for
control interface unit is limited to the removal and
adjusting power supply A1PS1.
replacement of defective subassemblies or chassis-
mounted parts, and the repair of defective wiring in
Test equipment
Common name
electrical equipment housing 1A1.  Refer to TM  11-
Multimeter AN/USM-223
6625-2951-13
for
maintenance
of
Tool Kit, Electronic Equipment
TK-105/G