TM 11-6825-2937-13
CHAPTER 5
DIRECT SUPPORT MAINTENANCE INSTRUCTIONS
Section I. GENERAL
5-1. Introduction Maintenance instructions presented in
equipment. Serious injury or DEATH may
this chapter apply primarily to Test Set, Electronic
result from contact with terminals carrying this
Systems TS-3796/UKM-4
(control-interface unit).
voltage.
Maintenance instructions for Test Set, Electronic
CAUTION
Systems AN/UYM-7 (digital tester) are given in TM 11-
When making resistance measurements
6625-2951-13. The following maintenance duties are
ensure that power is removed from the unit
assigned to direct support maintenance personnel:
being tested. Failure to comply may result in
erroneous readings or in damage to the
a.
Testing the control-interface unit to localize
equipment.
trouble to a faulty subassembly or chassis-
mounted part.
All procedures for making volta3e and
resistance
b.
Replacing faulty subassemblies or chassis-
measurements are contained in the troubleshooting
mounted parts.
procedures.
c.
Performing power supply adjustments.
d.
Repairing filter assembly AIFLI.
5-3.
Waveform Measurements
5-2.
Voltage and Resistance Measurements
ALL procedures for making waveform measurements
WARNING
are contained in the troubleshooting procedures.
Be careful when 115 V ac is applied to the
Section II. TOOLS AND EQUIPMENT
5-4.
Tools and Test Equipment Required
The tools and test equipment required for direct support maintenance are listed below.
Test equipment
Technical manual
Common name
Test Set, Electronic Systems AN/UYM-7
TM 116625-2951-13
Digital tester
Multimeter AN/USM-223
TM 11-6625-654-14
Oscilloscope AN/USM-281C
TM 11-6625-2658-14
Tool Kit, Electronics Equipment TK-105/G
SC 518 91C-RO7
Tool Kit
natural oils, prolonged contact with skin should
5-5. Materials Required
be avoided. When necessary, use gloves which
the solvent cannot penetrate. If the solvent is
The materials required for direct support maintenance
taken internally,
consult a physician
are listed below.
immediately.
WARNING
a.
Cleaning compound (tichlorotrifluoroethane).
Adequate ventilation should be provided while using
b.
Cleaning cloth.
TRICHLOROTRIFLUOROETHANE. Prolonged
c.
Detergent.
breathing of vapor should be avoided. The
d.
Fine bristle brush.
solvent should not be used near heat or open
e.
Fine sandpaper.
flame; the products of decomposition are toxic
f.
Silicone heatsink compound (Dow Corning 340).
and
irritating.
Since
TRICHLOROTRIFLUOROETHANE
dissolves
Section III. TROUBLESHOOTING
comprises a list of tools and test equipment required, a
5-6.
General
test setup diagram, a functional test procedure, a
WARNING
troubleshooting table, and additional data as required .
Be careful when 115V ac is applied to the
Malfunctions listed in the troubleshooting table are
equipment. Serious injury or DEATH may result
assumed to occur during testing of the control-interface
from contract with terminals carrying this voltage.
unit or its subassembles a s described in Section V The
entire test procedure should be repeated after repair to
This section contains information to aid in the direct
ensure that the malfunction was corrected.
support troubleshooting of the control-interface unit and
each repairable subassembly.
The troubleshooting
procedure
5-1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |