TM 11-6625-2884-30/NAVAIR 16-35TS3615-2
REPLACEMENT
OF
POWER
SUPPLIES
accomp ished by performing one of the following respective procedures.
Control Panel Assembly Power Supply 1A1PS1 (-15 Vdc). Remove Control
a.
Panel Assembly 1A1 from them in accordance with paragraph 3-32c and
perform the following:
(1) Place the control panel in an upside down position on the test
bench.
(2) Remove caution plate (1) - four pan head screws, lockwashers and
flat washers.
(3) Tag and unsolder the 115 Vac input wires (2) and the two output
wires (3) from Power Supply PSI.
(4) Remove pan head screw and lockwasher (4) securing PS1 to power
supply bracket.
(5) Remove pan head screw, lockwasher and flat washer (5), securing
the hold down bracket, between PS1 and PS3 (6).
(5) Lower and remove PS1 (7) with the hold down bracket and post (6).
REPLACEMENT
(1) Pos tion replacement -15 Vdc Power Suppl y 1A1PS1 (7) and bracket
a n d post (6) on control panel.
(2) Fasten 1A1PS1 to power supply bracket, using pan head screw and
lockwashers (4).
(3) Fasten hold down bracket and post (6) to power supply bracket,
using pan head screws, lockwasher and flat, washer (5).
(4) Solder 115 Vac input wires (2) and two output wires (3) to Power
Supply PS1, observing dc polarity.
(5) Install caution plate (1) with four pan head screws, lockwashers
and flat washers.
(6) Replace control panel in BTS according to paragraph 3-32d.
3-86
|