Click here to make tpub.com your Home Page

Page Title: TABLE 1-7. BTS SWITCH INFORMATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-6625-2884-30/NAVAIR 16-35TS3615-2
TABLE 1-7. BTS SWITCH INFORMATION
FUNCTION
SWITCH
1A1S1
LAMP TEST - Pushbutton switch, when pressed lights the JAM/
TEST/GO/NO-GO (1A1S4/D11) and INOP (1A1DS2) indica-
tors on the control panel assembly.
1A1S2
YIG FILTER IN OUT - Switch used to switch the YIG FILTER
(FL1) "IN" or "OUT" of the RF path in Status Panel
Assembly 1A2.
YIG FILTER CONTROL - Three decade thumbwheel switch used to
1A1S3
tune the YIG filter in the Status Panel Assembly 1A2.
OSCILLOSCOPE MONITOR - Dual concentric rotary 18 position
1A2S1
switch used for selecting 17 test points in the
LRU-1 under test or 1 signal from the RF Modulation
Assembly 1A3/1A4.
VOLTAGE MONITOR - Nine-position rotary switch used to
1A2S2
monitor the nine dc voltages in LRU-1 under test.
DET VIDEO/UUT SIGNAL - Two position toggle switch. When
1A2S3
in the DET VIDEO position, enables the monitoring
of detected RF from the LRU-1 under test. When in
the UUT position, enables the selection of one of 17
test points from LRU-1 under test, or 1 signal from
BTS via OSCILLOSCOPE MONITOR switch 1A2S1A.
RESET - Pushbutton switch - When pressed provides a master
1A2S4
reset signal to LRU-1 under test.
SORTER 1 LOAD - Alternate action pushbutton - When enabled,
1A2S5
sends a load command to sorter 1 of LRU-1 under
test.
SORTER 1 OVRD - Alternate action pushbutton - When enabled,
1A2S6
prevents sorter 1 from locking to any input signal.
SORTER 2 LOAD - Alternate action pushbutton - When enabled,
1A2S7
sends a load command to sorter 2 of LRU-1 under
test.
SORTER 2 OVRD - Alternate action pushbutton - When enabled,
1A2S8
prevents sorter 2 from locking to any input signal.
MOD DRIVE INHIBIT - Alternate action pushbutton - When en-
1A2S9
abled, scan modulation is disabled in LRU-1 under
test.
1-39

Privacy Statement - Press Release - Copyright Information. - Contact Us