TM 11-6625-2884-30/NAVAIR 16-35TS3615-2
TABLE 1-7. BTS SWITCH INFORMATION (Continued)
FUNCTION
SWITCH
NOISE INHIBIT - Alternate action pushbutton - When enabled
1A2S1O
inhibits random noise ECM in LRU-1 under test.
SW-3 INHIBIT - Alternate action pushbutton - When enabled
1A2S11
inhibits SW-3 ECM in LRU-1 under test.
CP - Alternate action pushbutton - When enabled inhibits
1A2S12
pulse program in LRU-1 under test.
LAMP TEST - Pushbutton switch - When pressed provides a
1A2S13
ground return to light the status signal lamps and
forcing function lamps on status panel.
SWITCH COAXIAL - Enabled by the YIG FILTER IN-OUT switch
1A2S14
on control panel.
IN Position - YIG filter and driver control (FL1)
is connected into the RF path of status panel.
OUT Position - YIG filter and driver control (FL1)
is disconnected from RF path.
1A2S15
SWITCH COAXIAL - Enabled by the YIG FILTER IN-OUT Switch on
control panel.
IN POSITION - YIG filter and driver control (FL1)
is connected into the RF path of status panel.
OUT POSITION - YIG filter and driver control (FL1)
is disconnected from RF path.
FREQ SEL (F1-F2-F3) - Three position toggle switch - Selects
1A3/1A4S1
the low, mid and high RF frequencies directed to
the UUT.
1A3/1A4S2
CS FREQ - Two decade thumbwheel switch- Sets conical scan
(CS) frequency in 1 Hz steps from O to 99.
OUT SEL (PULSE/CW) - Two position toggle switch - Selects
1A3/1A4S3
either pulse modulation of RF signal or Continuous
Wave (CW) RF output to LRU-1 under test.
1A3/1A4S4
PW - Two decade thumbwheel switch - Sets the pulse width
from 0.1 to 9.9 microseconds in 0.1 microsec steps.
1-40
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |