TM 11-6625-2884-12/NAVAIR 16-35TS3615-1
TABLE 2-4. RF MODULATION ASSEMBLY CONTROLS, INDICATORS
AND CONNECTORS
FUNCTION
DEVICE
REFERENCE
Provides overcurrent protection to the RF
115V AC 1-1/2 amp
MODULATION ASSEMBLY.
circuit breaker
FREQ SEL F1/F2/F3
Selects one of three preset RF frequencies.
three position toggle
SWitch
Controls level at RF OUT connector in 10 dB
TRANSMIT ATTENUATOR
steps.
0-60 DB rotary control
Controls level at RF OUT connector in 1 dB
TRANSMIT ATTENUATOR
0-9 DB rotary control
steps.
Permits selection of either PULSE or CW RF
OUT SEL PULSE/CW
output.
toggle switch
Permits selection of one of three preset
PRI OFF/VAR PRI/A-W/
PRI's, or variable PRI under control of
A-F/B rotary control
PRI MICROSEC switches.
Sets PRI when switch is in VAR PRI position.
PRI MICROSEC three
PRI range is 300 to 999 us in steps of 1 us.
section thumbwheel
control
Sets Pulse width in steps from O.luS to
PW MICROSEC two
9.9 us.
section thumbwheel
control
Sets CS frequency in 1 Hz steps from 1 Hz to
CS FREQ HZ two
99 Hz.
section thumbwheel
control
Permits selection of one of ten preset CS
CS MOD DEPTH DB
modulation depths in discrete steps
rotary control
from O to 25 dB.