3-1. Introduction
controls, indicators, connectors, and test points of Test
Set, Control Monitor-Recording Head AN/AYM-9. Figure
This section illustrates and describes the function of
controls, indicators, connectors, and test points of Test
connectors, and test points on Simulator, Monitor Input
Set, Control Monitor-Recording Head AN/ AYM-9.
SM-627/AYM-9.
The function of controls and
3-2. Operator's Controls, Indicators,
connectors on Case, Test Set CY-7117/AYM-9,
Connectors, and Test Points
including Polaroid Camera CU-5, are given in table 3-2
and illustrated in figures 3-2 and 3-10.
Table 3-1. Simulator, Monitor Input SM-627/A YM-9,
Controls, Indicators and Connectors (fig. 3-1)
Control, indicator or connector
Function
BCD+3 indicator lamps ................................................................................................... Light to indicate presence of binary coded decimal (+3) readout which
corresponds to various positions of Control-Monitor C-8338/
AYA-10 thumbwheel switches. Lamp indications are as follows:
Lamp
BCD + 3 bit
0
1
2
2
2
2
4
2
3
8
2
BCD + 3--PRESS TO TEST switch (pushbutton switch) .............................................. When pressed, lights BCD+ indicator lamps first purposes.
DECIMAL indicator lamps ............................................................................................... Lighted lamp indicates presence of decimal number which cor-
responds to selected positions of Control-Monitor C-8338/AYA-
10 thumbwheel switches.
DECIMAL-PRESS TO TEST switch (pushbutton switch)
When pressed, lights DECIMAL indicator lamps for test purposes.
BCD indicator lamps ....................................................................................................... Light to indicator presence of binary coded decimal readout which
corresponds to various positions of Control-Monitor C-8338/
AYA-10 thumbwheel switches. Lamp indications are as follows:
Lamp
BCD bit
0
1
2
1
2
2
2
4
2
BCD-PRESS TO TEST switch (pushbutton switch)
When pressed, lights BCD, BATTERY INDICATOR, SINGLE
PULSE INDICATOR, 6.3VAC, GO, +5V, and FAILURE indi-
cator lamps for test purposes
BATTERY INDICATOR lamp ......................................................................................... When BATTERY TEST switch is pressed, lights to indicate cor-
rect Control-Monitor C-8338/AYA-10 battery voltage.
When pressed, checks Control-Monitor C-8338/AYA-10 battery
BATTERY TEST switch (pushbutton switch)
voltage
-522VDC indicator lamp .................................................................................................. Lights to indicate presence of -522 volts dc output
+ 500VDC indicator lamp ................................................................................................ Light to indicate presence of + 500 volts dc output.
-80VDC indicator lamp.................................................................................................... Lights to indicate presence of -80 volts dc output.
+HORIZ test point ........................................................................................................... Provides means of monitoring + horizontal deflection signal.
-HORIZ test point ............................................................................................................ Provides means of monitoring -horizontal deflection signal.
+ VERT test point............................................................................................................ Provides means of monitoring + vertical deflection signal.
VERT test point ............................................................................................................... Provides means of monitoring -vertical deflection signal.
UNBLANKING test point ................................................................................................. Provides means monitoring unblanking signal.
3-1
|