TM 11-5895-1097-40
Table 3-3. Receiver Crystal Module Limits - Cont.
Table 3-3. Receiver Crystal Module Limits - Cont.
Module
Part No.
Act. Freq.
Limits
Module
Part No.
Act. Freq.
Limits
Marking
Marking
143.50
SM-D-706522-9
125.40
125.39750 -125.40250
144.00
SM-D-7065224
125.90
125.89749 -125.90251
143.60
SM-D-706522-8
125.50
125.49749 -125.50251
149.50
SM-D-706522-3
131.40
131.39738-31.402621
143.70
SM-D-706522-7
125.60
125.59749 -125 0251
150.20
SM-D-706522-2
132.10
132.09736- 132.10264
143.80
SM-D-706522-6
125.70
125.69749 -125.70251
150.80
SM-D706522-1
132.70
132.69735- 132.70265
143.90
SM-D-706522-5
125.80
125.79749 -125.80251
Section II. TOOL AND EQUIPMENT
3-7. Tool and Equipment Required
(3)
Repair Kit MK-772/U (NSN 5999-00-757-
The following list of tools and equipment are required to
7042).
perform general support maintenance on the TS3630/GRA1
(4) Signal Generator SG-1 112(V)2/U (NSN 6625-
14.
00- 500-6525).
a. Tools.
(5) Voltmeter, RF AN/URM-145 (NSN-6625-00-
(1) Tool Kit, Electronic Equipment TK-100/G (NSN
973- 3986).
(2) Tool Kit, Electronic Equipment TK-105/G (NSN
3-8. Repair Parts.
Repair parts are listed and illustrated in the repair parts and
b. Equipment.
special tools list (RPSTL) TM 115895109740P, covering
(1) Maintenance Kit MK-1752/GRA-114 (NSN
general support maintenance for this equipment. TM
5895-01-057-6263.
115895109720P will also be used where applicable.
(2) AN/USM-223 (NSN 6625-00-999-7465).
Section III. TROUBLESHOOTING
maintenance personnel with the information required to check
3-9. General Troubleshooting Information
and corrrelate all information from organizational maintenance
a. Troubleshooting at the general support maintenance
with the test equipment and tools available Perform the
category includes the techniques outlined for organizational
procedures contained in the troubleshooting tables in the order
maintenance and additional techniques required to isolate a
given. Do not proceed to the next action when the corrective
defective assembly and part. Paragraph 3-10 describes the
measures have already been taken to eliminate the trouble.
systematic procedure to be followed which will enable
(1) Defective material, such as piece parts,
maintenance personnel to isolate the cause of the trouble and
modules. or minor components, shall be recorded and
correct the fault.
identified by National stock number (NSN), inspected and
b. The first step is to trace the fault to a particular
verified as defective. All replaced equipment will be repaired,
module or assembly. This is called localization. Bench tests
or disposed of in accordance with AR 7551 and current
can be made by following the procedures in paragraph 3-6.
established procedures for general support.
c. The final step is to trace the fault to the defective part
(2) When replacing a part, make sure that the part
on an asssembly. This is called isolation.
is the same as the one being replaced. Refer to section IV
d. Localization and isolation of a fault are determined by
maintenance of test set, for instructions on assembly.
visual inspection, voltage measurements, and use of the
(3) When trouble has been localized to a stage,
troubleshooting charts. Visual inspection will locate many
either through performance of the tests given in your
faults without testing the circuits. All visual signs should be
troubleshooting charts, or other means, isolate the defective
observed and an attempt made to localize the fault.
part by measuring voltage at the test points and other points
NOTE
related to the stage suspected of being faulty.
In all tests the possibility of intermittent
WARNING
troubles should be investigated. Jarring
When troubleshooting this equipment, be
or tapping the equipment may expose
extremely careful. 120 volds AC is
this type of problem.
present in the power supply circuit.
3-10. Troubleshooting Procedures.
DEATH ON CONTACT or serious injury
a. General. The malfunction listed in tables 3-4 and 3-5
may result if safety precautions are not
are presumed to exist after all lower level troubleshooting
followed.
Do
not
make
internal
procedures and corrective measures have been performed.
The tables provide general support
connections alone. Always have another
person to help in the case of an accident.
Always disconnect the ac source, and
ground the part with a shorting
3-11
|