FUNCTIONING OF EQUIPMENT
nector provides an output to a frequency counter for
2-1. General
accurate readings. In addition, the test provides a
The TS3630/GRA114 is a solid state receiver used to
regulated dc power source for testing the AN/GRA114
test  crystal  modules  on  overtone  frequencies
receiver circuit cards.
corresponding to those in Radio Link, Sound Ranging
AN/GRA114. The test set provides a GO/NO GO
2-2. Block Diagram Description
indicator of crystal activity by means of lamps. ABNC con
Figure 2-1. TS-3630/GRA-114 Functional Block Diagram
a. Rcvr Xtal Circuit. The input signal, from the RF
coupled by the crystal filter FL1 to the second mixer Q5.
INPUT receptacle, is applied to the RCVR XTAL
This signal, in conjunction with the signal from the
MODULE under test. The module output is heterodyned
second local oscillator Q6, is heterodyned, producing the
by the first mixer (circuit card A2), producing the first
second if. signal. The second if. signal is then coupled,
intermediate frequency (if.) signal. This signal is then
2-1