TM1 6625-736-1 3&P
Processing Data ...
-- Pilot Trnsltlon -*
Next Test State: (selected test state)
Standby... While data Is loading.
No key presses are required. The CADU will automatically progress to the next screen.
NOTE
If channel errors occur you will be transferred to the ERRORS REPORTED screen to view the error
message(s). Press QUIT to exit and return to the Test State screen. If some, but not all of the
channels measured, "partial" will appear to the right of Test State.
If no data was acquired due to channel errors, 'failed' will appear to the right of Test State.
If the measurement was successful, a 'done' will appear to the right of the selected Test State.
If an unsuccessful test occurs, refer to the Troubleshooting section in chapter 4.
Proceed to the next Test State.
(k)
Veritfy Test State 1: 16_1 on the CADU is selected.
(1)
On the Electronic Test Set position ACC Signal Select to 1: 16. Press DO twice on the CADU.
(2)
The procedure will repeat as per step (a).
(I)
Verify Test State 1: 64_1 on the CADU is selected.
(1)
On the Electronic Test Set position ACC Signal Select to 1: 64. Press DO twice on the CADU.
(2)
The procedure will repeat as per step (j).
(m)
For Test States 1: 4_2, 1: 16_2 and 1: 64_2, connect ACC3 on the DAU to the connector ACC3 on the
Electronic Test Set using the 25-ft 54 mv/g Accelerometer Cable, part number 29105605.
(n)
For Test States 1: 4_2, 1: 16_2 and 1: 64_2, connect ACC4 on the DAU to the connector ACC4 on the
Electronic Test Set using the 50-ft 54 mv/g Accelerometer Cable, part number 29105600.
(o)
Verify Test State 1: 4_2 on the CADU is selected.
(1)
On the Electronic Test Set position ACC Signal Select to 1: 4. Press DO twice on the CADU.
(2)
The procedure will repeat as per step (1).
2-10
|