Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: (k) Veritfy Test State 1
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM1 6625-736-1 3&P Processing Data ... -- Pilot Trnsltlon -* Next Test State: (selected test state) Standby...  While data Is loading. No key presses are required.  The CADU will automatically progress to the next screen. NOTE If channel errors occur you will be transferred to the ERRORS REPORTED screen to view the error message(s).    Press  QUIT  to  exit  and  return  to  the  Test  State  screen.    If  some,  but  not  all  of  the channels measured, "partial" will appear to the right of Test State. If no data was acquired due to channel errors, 'failed' will appear to the right of Test State. If the measurement was successful, a 'done' will appear to the right of the selected Test State. If an unsuccessful test occurs, refer to the Troubleshooting section in chapter 4. Proceed to the next Test State. (k) Veritfy Test State 1:  16_1 on the CADU is selected. (1) On the Electronic Test Set position ACC Signal Select to 1:  16.  Press DO twice on the CADU. (2) The procedure will repeat as per step (a). (I) Verify Test State 1:  64_1 on the CADU is selected. (1) On the Electronic Test Set position ACC Signal Select to 1:  64.  Press DO twice on the CADU. (2) The procedure will repeat as per step (j). (m) For  Test  States  1:    4_2,  1:    16_2  and  1:    64_2,  connect  ACC3  on  the  DAU  to  the  connector  ACC3  on  the Electronic Test Set using the 25-ft 54 mv/g Accelerometer Cable, part number 29105605. (n) For  Test  States  1:    4_2,  1:    16_2  and  1:    64_2,  connect  ACC4  on  the  DAU  to  the  connector  ACC4  on  the Electronic Test Set using the 50-ft 54 mv/g Accelerometer Cable, part number 29105600. (o) Verify Test State 1:  4_2 on the CADU is selected. (1) On the Electronic Test Set position ACC Signal Select to 1:  4.  Press DO twice on the CADU. (2) The procedure will repeat as per step (1). 2-10

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business