TM 1-6625-735-14
Switch is Pressed and Held To TEST. (Cont)
TEST OR INSPECTION
CORRECTIVE ACTION
4. Release RATE GYRO TEST YAW control. Multimeter shall indicate 0.0 vdc.
Go to 5.
5. If multimeter indication is not correct, replace switch S17.
TABLE NO. 3-45. Multimeter Does Not Indicate Less Than 1.0 Ohm With FAULT MONITOR I
LIMIT 1 Switch Placed To INHIBIT And Does Not Indicate Greater Than 100K Ohms With FAULT
MONITOR I LIMIT 1 Switch Placed To NORM.
TEST OR INSPECTION
CORRECTIVE ACTION
1. Connect multimeter between NO. 1 I LIMIT SWITCHED and SIG GND test jacks.
Go to 2.
2. Place FAULT MONITOR I LIMIT 1 control to INHIBIT. Multimeter shall indicate
less than 1.0 ohm.
Step 1. If multimeter indication is not correct, replace switch S12.
Step 2. If multimeter indication is correct, go to 3.
3. Place FAULT MONITOR I LIMIT 1 control to NORM. Multimeter shall indicate
greater than 100K ohms. Go to 4.
4. If multimeter indication is not correct, replace switch S12.
TABLE NO. 3-46. Multimeter Does Not Indicate Less Than 1.0 Ohm With FAULT MONITOR I
LIMIT 2 Switch Placed To INHIBIT And Does Not Indicate Greater Than 100K Ohms With FAULT
MONITOR I LIMIT 2 Switch Placed To NORM.
TEST OR INSPECTION
CORRECTIVE ACTION
1. Connect multimeter between NO. 2 I LIMIT SWITCHED and SIG GND test jacks.
Go to 2.
2. Place FAULT MONITOR I LIMIT 2 control to INHIBIT. Multimeter shall indicate
less than 1.0 ohm.
3-38
|