TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
Mode Selector Control
NORM supplies No. 1 and No. 2 stabilator amplifier-pitch rate gyro output
signals through test set connectors J1 and J2, to No. 1 and No. 2 stabilator
amplifiers, respectively. NORM also supplies No. 1 stabilator amplifier-filtered
pitch rate output signal through test set connector J3 to SAS amplifier. Signal
from No. 1 stabilator amplifier-pitch rate gyro can be monitored at STAB 1
SNSR and STAB 1 SIM test points. No. 1 stabilator amplifier-filtered pitch
rate output signal can be monitored at SAS SNSR and SAS SIM test points.
GND supplies ground from test set through connectors J1, J2, and J3 to No. 1
stabilator amplifier, No. 2 stabilator amplifier, and SAS amplifier inputs,
respectively. These grounds can be monitored at STAB 1 SIM, STAB 2 SIM,
and SAS SIM test points. SIM STAB 1 & 2 supplies variable dc simulation
signal selected by NOSE DN/NOSE UP control through test set connectors J1
and J2 to No. 1 and No. 2 stabilator amplifiers, respectively. These simulation
signals can be monitored at STAB 1 SIM and STAB 2 SIM test points. This
position also supplies a ground through test set connector J3 to SAS amplifier.
This ground can be monitored at SAS SIM test point. SIM STAB 1 supplies
variable dc simulation signal selected by NOSE DN/NOSE UP control,
through test set connector J1 to No. 1 stabilator amplifier. This simulation sig-
nal can be monitored at STAB 1 SIM test point. SIM STAB 1 position also
supplies No. 1 stabilator amplifier-filtered pitch rate output signal through test
set connector J3 to SAS amplifier. This filtered pitch rate signal can be moni-
tored at SAS SIM test point. SIM STAB 1 also supplies ground through test
set connector J2 to No. 2 stabilator amplifier. This ground can be monitored at
STAB 2 SIM test point. SIM STAB 2 supplies variable dc simulation signal
selected by NOSE DN/NOSE UP control, through test set connector J2 to No.
2 stabilator amplifier. This simulation signal can be monitored at STAB 2 SIM
test point. SIM STAB 2 also supplies ground, through test set connectors J1
and J3, to No. 1 stabilator amplifier and SAS amplifier, respectively. These
grounds can be monitored at STAB 1 SIM and SAS SIM test points. SIM SAS
1 supplies variable dc simulation signal selected by NOSE DN/NOSE UP con-
trol, through test set connector J3 to SAS amplifier. This simulation signal can
be monitored at SAS SIM test point. SIM SAS 1 position also supplies ground
from test set through connectors J1 and J2, to No. 1 and No. 2 stabilator
amplifiers, respectively. These grounds can be monitored at STAB 1 SIM and
STAB 2 SIM test points. SIM SAS (WO) supplies variable dc simulation sig-
nal selected by NOSE DN/NOSE UP control through test set connector J3 to
SAS amplifier. This simulation signal can be monitored at SAS SIM test point.
SIM SAS (WO) position also shorts out capacitor in SAS amplifier, allowing
gain checks to be done using steady state dc simulation signal from NOSE
DN/NOSE UP control. SIM SAS (WO) also supplies ground from test set
through connectors J1 and J2, to No. 1 and No. 2 stabilator amplifiers, respec-
tively. These grounds can be monitored at STAB 1 SIM and STAB 2 SIM test
points.